Parameters of building materials.
| Project | Material | d | ρ | λ | с | r | ε | (mm) | (kg/m³) | (W/m K) | (J/kg K) | (m2K/W) |
| Roof | Clay tile | 20 | 2000 | 1 | 800 | 0.02 | 0.91 |
| Floor | Cement mortar | 20 | 1800 | 0.93 | 1050 | 0.1 | 0.96 | Concrete | 100 | 2500 | 1.74 | 920 | — | Cement mortar | 20 | 1800 | 0.93 | 1050 | 0.96 |