Research Article

Characteristic Analysis of Digital Large Flow Emulsion Relief Valve

Table 2

Dynamic response indexes of relief valve.

Pilot valveMain valve
Stable pressure (MPa)OvershootStable time (ms)Steady-state pressure (MPa)OvershootStable time (ms)

1.2 mm18.950.13127.7544.550.05030
0.9 mm
 = 1.2 mm19.450.11825.2545.000.04724.25
0.9 mm19.450.10525.545.000.03924.75
1.2 mm