Research Article

Memetic Salp Swarm Algorithm-Based Frequency Regulation for Power System with Renewable Energy Integration

Table 4

Comparison on convergence results obtained by different methods.

MethodPower deviation

80PROP32.0019.2012.809.606.40676.95
GA15.5223.1817.9212.710.68529.86
SSA10.6125.7417.2614.6711.72471.48
MSSA14.2620.8419.5215.1210.26402.451

−50PROP−23.81−14.29−4.76−2.38−4.76479.83
GA−4.26−23.24−10.02−3.86−8.62274.26
SSA−8.65−20.62−9.85−4.29−6.59307.48
MSSA−4.48−20.69−9.14−5.58−10.11234.254