Research Article

Numerical Simulation of the Natural Convection with Presence of the Nanofluids in Cubical Cavity

Table 3

Mesh sensitivity of the average Nusselt number to the grid sizes.

41 × 41 × 4151 × 51 × 5161 × 61 × 6171 × 71 × 7181 × 81 × 81

Numoy4.9486854.9215634.8984854.8952354.892066