Research Article

Network Coordination, Self-Regulation Mode, and Autonomous Control Space Planning of Microgrid

Table 4

Line impedance of 33-node system.

Initial nodeFinal nodeLine resistance (p.u.)Line reactance (p.u.)Initial nodeFinal nodeLine resistance (p.u.)Line reactance (p.u.)

120.0575260.0293243230.2815150.192356
340.2283570.11630023240.5602850.442425
450.2377780.12110424250.5590370.437434
560.5109950.4411156260.1266570.064514
670.1167990.38608526270.1773200.090282
780.4438600.14668527280.6607370.582559
890.6426430.46170528290.5017610.437122
10110.1226640.04055530310.6079530.600840
11120.2335980.07724231320.1937290.225799
12130.9159220.72063432330.2127590.330805
13140.3379180.4447962181.2478511.247851
14150.3687400.3281859151.2478511.247851
15160.4656350.34003912221.2478511.247851
16170.8042401.07377518330.3119630.311963
17180.4567130.35813325290.3119630.311963
2190.1023240.0976442340.3075950.156668
19200.9385080.8456689350.6513780.461705
20210.2554970.29848629360.3166420.161285
21220.4423010.584805