Research Article

Path Planning and Setup Orientation for Automated Dimensional Inspection Using Coordinate Measuring Machines

Table 1

PAD matrix for the gearbox.

Setups/no. of featuresPAD matrix
Total in +xTotal in −xTotal in +yTotal in −yTotal in −z

Bottom17171000
Top17170100
Front1717000
Rear1717000
Left0010017
Right000100
Total6868202017