Research Article
Numerical Study of Heat Transfer and Optimum Design for Trench Laying Cables with Ceramic Plates
Table 3
The detailed mesh settings for different grids.
| Grid | Regions | Maximum grid size (m) | Minimum grid size (m) | Total element numbers |
| Grid 1 | Zone 1 | 0.3606 | 0.0044 | 8783 | Zone 2 | 0.0334 | 0.0033 | Zone 3 | 0.0097 | 0.0016 |
| Grid 2 | Zone 1 | 0.2717 | 0.0032 | 21361 | Zone 2 | 0.0186 | 0.0031 | Zone 3 | 0.0054 | 0.0012 |
| Grid 3 | Zone 1 | 0.0407 | 0.0026 | 48516 | Zone 2 | 0.0104 | 0.0025 | Zone 3 | 0.0032 | 0.0011 |
| Grid 4 | Zone 1 | 0.0369 | 0.0011 | 89812 | Zone 2 | 0.0099 | 0.0010 | Zone 3 | 0.0015 | 0.0006 |
|
|