Research Article

Comparison and Analysis of the Influence of Different Data Transformation Methods on the Fault Identification of Flexible DC Transmission Lines by Convolutional Neural Network

Table 5

Comparison of classification accuracy of different algorithms using a data transformation method.

Data conversion (%)Classification algorithm
BYSCARTKNNBAGSVMCNN

Unconvert89.1793.4696.2096.8478.9596.90
EMD85.9794.0992.0197.3693.4597.30
WT86.3094.2197.9398.2097.9699.20
FFT89.7094.9499.5698.5099.0599.80
VMD93.0998.3898.5898.3899.4699.88