Research Article

Automated Detection of Arrhythmia for Hybrid Neural Network of LSTM-Residual with Multi-Information Fusion

Table 3

Confusion matrix-intrapatient model (segment and beat).

 Predicated labelSpe (%)Sen (%)
NSVEBVEBF

True labelN17818222994.5698.13
SVEB604964299.8588.2
VEB30613461699.9596.28
F240314199.8683.92

Overall Acc: 99.11%.