Research Article

Automated Detection of Arrhythmia for Hybrid Neural Network of LSTM-Residual with Multi-Information Fusion

Table 4

Confusion matrix-intrapatient model (only beat).

 Predicated labelSpe (%)Sen (%)
NSVEBVEBF

True labelN177744927191.2699.56
SVEB924664099.7482.9
VEB4411352199.7496.71
F4801610499.9962

Overall Acc: 98.58%.