Research Article
Automated Detection of Arrhythmia for Hybrid Neural Network of LSTM-Residual with Multi-Information Fusion
Table 9
Comparison of the proposed method against existing methods.
| Paper | Method | Database | Acc (%) | Sen (%) |
| 25 | PCA + DTW + SVM | MITDB | 97.80 | 88.83 | 26 | CNN + MLP | MITDB | 96.27 | 68.55 | 27 | CWT + CNN | MITDB | 98.74 | 67.47 | 28 | Adversarial domain adaptation | MITDB | 92.30 | | Proposed | LSTM + residual network | MITDB | 99.11 | 91.63 |
|
|