Research Article
Numerical Simulation on Flow Field and Design Optimization of a Generator Unit Based on Computational Fluid Dynamics Analysis
Table 1
Air quantity evaluation for the optimized silent type generator unit.
| Designs | Total mass of air (kg/s) | Middle air inlet (kg/s) | Left air inlet (kg/s) | Right air inlet (kg/s) | Motor area (kg/s) | Radiator (kg/s) | Air quantity improvement of radiator (%) |
| Origin | 3.202 | 3.017 | 1.792 | 0.614 | 0.611 | 0.598 | 7.31 | Opt1 | 3.202 | 2.261 | 0.459 | 0.482 | 0.602 | 2.585 | 7.31 | Opt2 | 3.279 | 1.644 | 0.776 | 0.859 | 0.603 | 2.705 | 12.29 | Opt3 | 4.677 | 2.444 | 0.806 | 0.822 | 0.605 | 3.477 | 44.33 |
|
|