Research Article
Near-Field Measurements of Water-Entry Sound of Low-Speed Metal Balls in a Non-Anechoic Tank
| Experiment | Working conditions | Parameters |
| 1 | Virtual-source integration in time domain for near-field validation | Entry angle θ = 90° | Horizontal measuring distance L = 0.45 m | Entry speed = 9.02 m/s | Ball size D = 6, 8, 10, 12 mm |
| 2 | Fixed ball size, different entry speeds in near-field | Ball size D = 8 mm | Entry speed = 5.89, 6.37, 6.82, 7.14, 7.54, 7.92 m/s | Entry angle θ = 90° | Horizontal measuring distance L = 0.45 m |
| 3 | Fixed entry speed, different ball sizes in near-field | Ball size D = 4, 6, 8, 10, 12, 14, 16, 18, 20 mm | Entry speed = 5.89 m/s | Entry angle θ = 90° | Horizontal measuring distance L = 0.45 m |
|
|