The inverter system parameters.
| | Description | Value |
| | Frequency f | 50 Hz | | DC side voltage Udc | 360V | | Stator resistance Rs | 0.435 Ω | | Rotor resistance Rr | 0.816 Ω | | Stator leakage inductance Lls | 4 mH | | Rotor leakage inductance Lrs | 2 mH | | Mutual inductance Lm | 69.31 mH | | Pole pair p | 2 | | Moment of inertia J | 0.089 kg·m2 |
|
|