Research Article
The Diagnostic Method for Open-Circuit Faults in Inverters Based on Extended State Observer
Table 6
Comparison of the proposed fault diagnosis method and other fault methods.
| | Fault diagnosis method | Objector | Diagnosis time | Robustness | Cost | Fault type |
| | The neural network method | Both | More than one cycle | Low | Low | Single | | The fuzzy logic method | Both | More than one cycle | Medium | High | Multiple | | Park’s vector approach | Open-loop | More than one cycle | Low | Low | Single | | Spectrum analysis method | Both | More than one cycle | Medium | High | Single | | The proposed method | Both | About 1/3 cycle | High | Low | Multiple |
|
|