Research Article
Free Vibration Investigations of Rotating FG Beams Resting on Elastic Foundation with Initial Geometrical Imperfection in Thermal Environments
Table 5
The first nondimensional frequency of the cantilever FGM beam depends on
and
.
| | | n | 0 | 0.2 | 1 | 2 | 5 | 10 |
| 0 | 0 | 18.6497 | 17.0410 | 14.7543 | 13.9080 | 13.1900 | 12.8903 | 1 | 18.7891 | 17.1703 | 14.8700 | 14.0184 | 13.2956 | 12.9943 | 2 | 18.9239 | 17.2951 | 14.9814 | 14.1244 | 13.3970 | 13.0941 |
| 10 | 0 | 18.9155 | 17.2852 | 14.9677 | 14.1099 | 13.3821 | 13.0784 | 1 | 19.0530 | 17.4127 | 15.0818 | 14.2187 | 13.4862 | 13.1810 | 2 | 19.1860 | 17.5358 | 15.1916 | 14.3233 | 13.5861 | 13.2793 |
| 20 | 0 | 19.1777 | 17.5259 | 15.1781 | 14.3089 | 13.5714 | 13.2639 | 1 | 19.3133 | 17.6517 | 15.2907 | 14.4162 | 13.6741 | 13.3650 | 2 | 19.4445 | 17.7732 | 15.3990 | 14.5194 | 13.7726 | 13.4620 |
|
|