Research Article

First and Second Law Evaluation of Multipass Flat-Plate Solar Air Collector and Optimization Using Preference Selection Index Method

Table 4

Results of preference selection index Ω and ranking for 5 best cases (ranking 1 to 5) and 5 worst cases (ranking 131 to 135).

Case, iCollector typeAir mass flow rate m, kg/sCollector length L, mChannel depth H, mObjectivesΩRanking
ηEffNplateηII

710.012.50.020.520940.047330.84931
6130.012.50.020.462930.038640.84232
7030.0152.50.020.534430.032730.83793
810.012.50.0250.50940.046260.83574
410.0120.020.550440.042660.83195
12050.0151.50.030.441230.015010.6662131
10040.021.50.020.612540.013020.6571132
11450.0120.030.35630.019420.6531133
11150.011.50.030.369430.015890.6354134
1910.021.50.020.651340.0052870.6231135