Table 4
Results of preference selection index Ω and ranking for 5 best cases (ranking 1 to 5) and 5 worst cases (ranking 131 to 135).
| Case, i | Collector type | Air mass flow rate m, kg/s | Collector length L, m | Channel depth H, m | Objectives | Ω | Ranking | ηEff | Nplate | ηII |
| 7 | 1 | 0.01 | 2.5 | 0.02 | 0.5209 | 4 | 0.04733 | 0.8493 | 1 | 61 | 3 | 0.01 | 2.5 | 0.02 | 0.4629 | 3 | 0.03864 | 0.8423 | 2 | 70 | 3 | 0.015 | 2.5 | 0.02 | 0.5344 | 3 | 0.03273 | 0.8379 | 3 | 8 | 1 | 0.01 | 2.5 | 0.025 | 0.509 | 4 | 0.04626 | 0.8357 | 4 | 4 | 1 | 0.01 | 2 | 0.02 | 0.5504 | 4 | 0.04266 | 0.8319 | 5 | 120 | 5 | 0.015 | 1.5 | 0.03 | 0.4412 | 3 | 0.01501 | 0.6662 | 131 | 100 | 4 | 0.02 | 1.5 | 0.02 | 0.6125 | 4 | 0.01302 | 0.6571 | 132 | 114 | 5 | 0.01 | 2 | 0.03 | 0.356 | 3 | 0.01942 | 0.6531 | 133 | 111 | 5 | 0.01 | 1.5 | 0.03 | 0.3694 | 3 | 0.01589 | 0.6354 | 134 | 19 | 1 | 0.02 | 1.5 | 0.02 | 0.6513 | 4 | 0.005287 | 0.6231 | 135 |
|
|