Research Article

Experimental Study and Direct Strength Method for Cold-Formed Steel Built-Up I-Sectional Columns under Axial Compression

Table 6

Comparison on load capacities for built-up columns with and without the end fastener group.

Built-up columnsL (mm)λBuckling modesPA (kN)(PA2 − PA1)/PA1 (%)

DC10010-15-S150-N-S150029.65L + D129.400.15
DC10010-15-S150-Y-SL + D129.60
DC10010-15-S300-N-SL + D127.510.64
DC10010-15-S300-Y-SL + D128.32
DC10010-15-S450-N-SL + D122.804.07
DC10010-15-S450-Y-SL + D127.80

DC10010-20-S150-N-S200039.53L + D119.290.79
DC10010-20-S150-Y-SL + D120.24
DC10010-20-S300-N-SL + D117.922.15
DC10010-20-S300-Y-SL + D120.46
DC10010-20-S450-N-SL + D113.205.54
DC10010-20-S450-Y-SL + D119.47

DC7510-15-S150-N-S150037.53L + D92.211.49
DC7510-15-S150-Y-SL + D93.58
DC7510-15-S300-N-SL + D91.31.42
DC7510-15-S300-Y-SL + D92.6
DC7510-15-S450-N-SL + D87.634.42
DC7510-15-S450-Y-SL + D91.5

DC7510-20-S150-N-S200050.04L + D87.432.85
DC7510-20-S150-Y-SL + D89.92
DC7510-20-S300-N-SL + D86.682.40
DC7510-20-S300-Y-SL + D88.76
DC7510-20-S450-N-SL + D82.85.80
DC7510-20-S450-Y-SL + D87.6