Research Article
Natural Gas Hydrate Prediction and Prevention Methods of City Gate Stations
Table 1
Comparison of inhibitor injection volume calculation.
| | Temperature before throttling (°C) | Water dew point (°C) | Injection volume of methanol L (104 Nm3) | Injection volume of ethanol L (104 Nm3) | Injection volume of ethylene glycol L (104 Nm3) | | HYSYS | Program | Abs. e | HYSYS | Program | Abs. e | HYSYS | Program | Abs. e |
| | −5 | −5 | 3.02 | 3.01 | 0.01 | 3.24 | 3.26 | 0.02 | 0.89 | 0.87 | 0.02 | | −6 | 2.95 | 2.94 | 0.01 | 3.19 | 3.19 | 0 | 0.77 | 0.76 | 0.01 | | −7 | 2.88 | 2.88 | 0 | 3.12 | 3.13 | 0.01 | 0.68 | 0.66 | 0.02 | | −8 | 2.82 | 2.82 | 0 | 3.06 | 3.07 | 0.01 | 0.58 | 0.56 | 0.02 | | −9 | 2.76 | 2.77 | 0.01 | 3.00 | 3.02 | 0.02 | 0.47 | 0.47 | 0 |
| | −10 | −10 | 2.76 | 2.67 | 0.09 | 2.86 | 2.92 | 0.06 | 0.95 | 0.91 | 0.04 | | −11 | 2.69 | 2.61 | 0.08 | 2.81 | 2.86 | 0.05 | 0.84 | 0.80 | 0.04 | | −12 | 2.63 | 2.56 | 0.07 | 2.75 | 2.81 | 0.06 | 0.75 | 0.70 | 0.05 | | −13 | 2.57 | 2.51 | 0.06 | 2.70 | 2.76 | 0.06 | 0.64 | 0.61 | 0.03 | | −14 | 2.52 | 2.45 | 0.07 | 2.65 | 2.7 | 0.05 | 0.56 | 0.52 | 0.04 |
|
|