Research Article

Natural Gas Hydrate Prediction and Prevention Methods of City Gate Stations

Table 1

Comparison of inhibitor injection volume calculation.

Temperature before throttling (°C)Water dew point (°C)Injection volume of methanol L (104 Nm3)Injection volume of ethanol L (104 Nm3)Injection volume of ethylene glycol L (104 Nm3)
HYSYSProgramAbs. eHYSYSProgramAbs. eHYSYSProgramAbs. e

−5−53.023.010.013.243.260.020.890.870.02
−62.952.940.013.193.1900.770.760.01
−72.882.8803.123.130.010.680.660.02
−82.822.8203.063.070.010.580.560.02
−92.762.770.013.003.020.020.470.470

−10−102.762.670.092.862.920.060.950.910.04
−112.692.610.082.812.860.050.840.800.04
−122.632.560.072.752.810.060.750.700.05
−132.572.510.062.702.760.060.640.610.03
−142.522.450.072.652.70.050.560.520.04