Research Article

Study on Numerical Simulation of Fire Danger Area Division in Mine Roadway

Table 6

Classification results of different smoke danger zones.

TimeIndexSafe area (I) (m)Slightly dangerous area (II) (m)Moderately dangerous area (III) (m)Highly dangerous area (IV) (m)

10 sCO(0,1.3)∪(4.2,11)(1.3,1.5)∪(3.6,4.2)(1.5,1.6)∪(3.2,3.6)(1.6,3.2)
CO2(0,1.5)∪(3.3,11)(1.5,1.6)∪(2.7,3.3)(1.6,1.8)∪(2.2,2.7)(1.8,2.2)

20 sCO(0,1.3)∪(5.7,11)(1.3,1.5)∪(5,5.7)(1.5,1.6)∪(4.4,5)(1.6,4.4)
CO2(0,1.5)∪(4.6,11)(1.5,1.6)∪(4.1,4.6)(1.6,1.8)∪(3.6,4.1)(1.8,3.6)

30 sCO(0,1.3)∪(9.5,11)(1.3,1.5)∪(8.5,9.5)(1.5,1.6)∪(7.6,8.5)(1.6,7.6)
CO2(0,1.5)∪(7.8,11)(1.5,1.6)∪(7.1,7.8)(1.6,1.8)∪(6,7.1)(1.8,6)

40 sCO(0,1.3)(1.3,1.5)∪(10.6,11)(1.5,1.6)∪(9.6,10.6)(1.6,9.6)
CO2(0,1.5)∪(9.9,11)(1.5,1.6)∪(9,9.9)(1.6,1.8)∪(7.5,9)(1.8,7.5)

50 sCO(0,1.3)(1.3,1.5)(1.5,1.6)∪(10.6,11)(1.6,10.6)
CO2(0,1.5)(1.5,1.6)∪(10.9,11)(1.6,1.8) ∪(8.7,10.9)(1.8,8.7)

60 sCO(0,1.3)(1.3,1.5)(1.5,1.6)(1.6,11)
CO2(0,1.5)(1.5,1.6)(1.6,1.8)∪(9.8,11)(1.8,9.8)