Research Article

Analysis on the Influence Mechanism of Cooling Water on Turbocharger and Optimum Coolant Mass Flow Rate Intelligent Prediction

Table 2

Difference between the experimental data and simulation data.

Exhaust temperature (°C)Water inlet temperature (°C)Water outlet temperature (°C)Relative error (%)
ExperimentSimulation

813.795.5100.299.40.80
763.4959898.20.20
752.49597.797.90.20
743.69597.497.80.41
737.39597.297.70.51
732.6949796.60.41
725.19496.696.50.10
717.89496.296.40.21