Ultimate Limit Design of Strengthened Steel Columns by Mortar-Filled FRP Tubes
Table 4
Experimental and theoretical ultimate load-bearing capacities.
Specimens
Failure mode
Pexp (kN)
Pth (kN)
Difference between Pth and Pexp
PFeng2013 (kN) (corresponding to GB)
C70-5
LB
513.9
485.1 (LB)
−5.6%
—
C105-0
FS1
415.2
415.7 (FS)
0.1%
—
C105-2
FR (no discussion)
443.5
—
—
C105-5
FS2
435.5
415.7 (FS)
−4.5%
C140-5
GB
357.6
430.0 (GB)
20.2%
520.7
C175-5
GB
316.4
305.8 (GB)
−3.4%
339.5
I70-5
LB
421.1
466.5 (LB)
10.8%
—
I105-0
FS1
472.0
474.5 (FS)
0.5%
—
I105-2
LB
528.9
483.4 (LB)
−8.6%
I105-5
Machine malfunction
—
—
—
I140-5
LB
428.5
483.4 (LB)
12.8%
—
I175-5
GB
386.8
429.3 (GB)
11.0%
894.9
LB, local buckling at end of steel member; FS1 and FS2, FRP-tube splitting at end or on inside of wrapped area; FR, FRP-fabrics rupture; GB, global buckling.