Research Article
Optimal Design Method for Inner-Intrinsically Safe Buck-Boost Converters Based on Ignition Capability
Table 6
Explosive test results (
= 22 V,
= 18 V,
C = 22
μF,
= 36 Ω, and
f = 200 kHz).
| Design range | Critical value | Inductance (μH) | Results |
| Unsafe | | 20 | Exploded | 35 | Unexploded |
| Inner-intrinsically safe | | 38.29 | Unexploded | 50 | Unexploded | | 137.78 | Unexploded | 300 | Unexploded | | 508.98 | Unexploded |
| Unsafe | | 520 | Unexploded | 900 | Exploded | 1095.11 | Exploded | 1500 | Exploded |
|
|