Research Article

Optimal Design Method for Inner-Intrinsically Safe Buck-Boost Converters Based on Ignition Capability

Table 6

Explosive test results ( = 22 V,  = 18 V, C = 22 μF,  = 36 Ω, and f = 200 kHz).

Design rangeCritical valueInductance (μH)Results

Unsafe20Exploded
35Unexploded

Inner-intrinsically safe38.29Unexploded
50Unexploded
137.78Unexploded
300Unexploded
508.98Unexploded

Unsafe520Unexploded
900Exploded
1095.11Exploded
1500Exploded