Research Article

Investigation of Counterflow Microchannel Heat Exchanger with Hybrid Nanoparticles and PCM Suspension as a Coolant

Table 1

Bottom channel (hot fluid) (0 ≤ y ≤ Hh).

LocationBoundary conditionComments

At x = 0uh = uhi,  =  = 0, Th = ThiHot fluid inflow
At x = LHot fluid outflow (fully developed flow, end of the channel)
At y = 0uh= =  = 0No-slip, adiabatic wall
At y = Hhuh =  =  = 0, Th = TsFluid-solid interface (no-slip, conjugate heat transfer)
At z = 0uh== = 0No-slip, adiabatic wall
At z = Wchuh = = = 0No-slip, adiabatic wall