Research Article

Simulation Analysis of Magnetic Gradient Full-Tensor Measurement System

Table 3

RMSE comparison of measured values of seven kinds of magnetic gradient full-tensor system.

TensorStructures
Cross shapeEquilateral triangle shapeRight triangle shapeSquare shapeRegular tetrahedron shapeRight-angle tetrahedron shapeRight triangle shape

Bxx (nT/m)0.00930.24680.56520.00110.05650.56520.0187
Bxy (nT/m)0.00660.12200.41820.01010.10360.41820.0133
Bxz (nT/m)0.00800.29230.49770.00860.13660.49770.0161
Byy (nT/m)0.00900.12170.39290.01642.91410.39297.8728
Byz (nT/m)0.00190.26130.47360.02073.55120.47360.0039