Research Article
Prediction Modeling and Sensitivity Analysis of Robot Bone Milling Temperature Operated by a Doctor
Table 1
Experiment sequence and data results.
| | Serial number | Order | A (r/min) | B (mm/s) | C (mm) | T1 (°C) | T2 (°C) | T3 (°C) | T4 (°C) |
| | 8 | 2 | 3000 | 120 | 0.3 | 43.2 | 46 | 47.6 | 41 | | 12 | 3 | 2000 | 120 | 0.2 | 35.4 | 38.6 | 40 | 33.1 | | 19 | 4 | 2000 | 75 | 0.2 | 37 | 40.8 | 42.1 | 35 | | 6 | 5 | 3000 | 30 | 0.3 | 49 | 51.7 | 53 | 46.9 | | 11 | 6 | 2000 | 30 | 0.2 | 41.2 | 44 | 45.7 | 39 | | 10 | 7 | 3000 | 75 | 0.2 | 42 | 45.2 | 46.6 | 39.7 | | 3 | 8 | 1000 | 120 | 0.1 | 23 | 26.1 | 27.9 | 21 | | 2 | 9 | 3000 | 30 | 0.1 | 45.1 | 48 | 49.3 | 43 | | 17 | 10 | 2000 | 75 | 0.2 | 37.2 | 40.3 | 41.9 | 35.1 | | 13 | 11 | 2000 | 75 | 0.1 | 36.1 | 39 | 41 | 33.8 | | 9 | 12 | 1000 | 75 | 0.2 | 25.8 | 29 | 30.4 | 23.6 | | 20 | 13 | 2000 | 75 | 0.2 | 36.8 | 39.8 | 41.5 | 34.6 | | 18 | 14 | 2000 | 75 | 0.2 | 37.1 | 40 | 41.6 | 35 | | 5 | 15 | 1000 | 30 | 0.3 | 32.9 | 36.1 | 37.6 | 30.7 | | 14 | 16 | 2000 | 75 | 0.3 | 39.8 | 43 | 44.2 | 37.5 | | 7 | 17 | 1000 | 120 | 0.3 | 27 | 30 | 31.6 | 24.9 | | 15 | 18 | 2000 | 75 | 0.2 | 37 | 40 | 41.3 | 34.8 | | 16 | 19 | 2000 | 75 | 0.2 | 37.1 | 40.2 | 41.7 | 35 | | 1 | 20 | 1000 | 30 | 0.1 | 29 | 31.3 | 32.8 | 27 |
|
|