Research Article
Analytical Calculation of Critical Anchoring Length of Steel Bar and GFRP Antifloating Anchors in Rock Foundation
Table 2
Calculating parameters and anchoring length of GFRP anchors.
| Anchor test source | r0 (mm) | μs | Esa (GPa) | Es (MPa) | Test anchoring length (m) | Theoretical critical anchoring length (m) |
| [17] | 14 | 0.33 | 51 | 32 | 5 | 5.871 | [18] | 14 | 0.33 | 45 | 32 | 6.45 | 5.514 | [23] | 14 | 0.33 | 51 | 30 | 3 | 6.063 | [24] | 16 | 0.25 | 43 | 3.05 × 103 | 0.65 | 0.624 |
|
|