Failure probability and sensitivity results of Example 3.

Proposed methodMCS (N = 5 × 106)

9.7363 × 10−42.8000 × 10−4
/∂μa−8.2470 × 10−4−5.0299 × 10−4
/∂σa1.0579 × 10−41.1908 × 10−4
/∂μt−2.2000 × 10−3−2.0500 × 10−3
/∂σt1.1000 × 10−31.4000 × 10−3
/∂μb−4.4905 × 10−4−5.8711 × 10−4
/∂σb3.2129 × 10−41.8541 × 10−4
/∂μh−5.5812 × 10−4−6.4358 × 10−4
/∂σh1.1000 × 10−31.5000 × 10−3
/∂μl9.3914 × 10−58.9505 × 10−5
/∂σl1.9045 × 10−41.9436 × 10−4
/∂μF5.5696 × 10−61.5504 × 10−6
/∂σF8.4887 × 10−58.8620 × 10−7
/∂μd−1.9000 × 10−3−2.1000 × 10−3
/∂σd1.6000 × 10−31.5000 × 10−3
/∂μE−2.2514 × 10−7−3.6546 × 10−7
/∂σE1.8949 × 10−72.5002 × 10−7