Research Article

A Novel Method for Fault Diagnosis of the Two-Input Two-Output Nonlinear Mass-Spring-Damper System Based on NOFRF and MBPCA

Table 2

The recognition rate with different kernel functions.

Fault numberFault modeRecognition rate
Linear kernel (%)Polynomial kernel (%)GRB kernel (%)ERB kernel (%)MLP kernel (%)

F0Normal96971009597
F1 increased8787888582
F2 decreased7894929582
F3 increased8597989385
F4 and increased8185919086