Research Article

Reliability Analysis of Gasifier Lock Bucket Valve System Based on DBN Method

Table 1

The DBN nodes of the gasifier lock bucket valve system.

NodeName of the nodeReference

TGasifier lock bucket valve[2]
M1Sealing surface wear[31]
M2Switch not in place[32, 33]
X1High-pressure pulverized coal scour[2, 31, 34]
X2Valve ball and ball seat wear[31]
X3Ball seat stick together[2]
X4Deformation and wear of interior parts[31, 34]
X5Pulverized coal accumulation[2]
X6The actuator output torque is insufficient[33, 34]
X7Bearing internal adhesion under high pressure[2, 31, 34]
X8The pulverized coal enters during the switching process[35]
X9Water quality is poor[31]
X10Valve frequent switch[2, 33]
X11Short time to collect slag[32, 36, 37]
X12Pressure reducing too fast results in three-phase current scour[32]