Research Article
Reliability Analysis of Gasifier Lock Bucket Valve System Based on DBN Method
Table 1
The DBN nodes of the gasifier lock bucket valve system.
| Node | Name of the node | Reference |
| T | Gasifier lock bucket valve | [2] | M1 | Sealing surface wear | [31] | M2 | Switch not in place | [32, 33] | X1 | High-pressure pulverized coal scour | [2, 31, 34] | X2 | Valve ball and ball seat wear | [31] | X3 | Ball seat stick together | [2] | X4 | Deformation and wear of interior parts | [31, 34] | X5 | Pulverized coal accumulation | [2] | X6 | The actuator output torque is insufficient | [33, 34] | X7 | Bearing internal adhesion under high pressure | [2, 31, 34] | X8 | The pulverized coal enters during the switching process | [35] | X9 | Water quality is poor | [31] | X10 | Valve frequent switch | [2, 33] | X11 | Short time to collect slag | [32, 36, 37] | X12 | Pressure reducing too fast results in three-phase current scour | [32] |
|
|