Research Article
Reliability Analysis of Gasifier Lock Bucket Valve System Based on DBN Method
Table 2
Failure rates of prior distribution of each node of the gasifier lock bucket valve system.
| | Node | Name of the node | Failure rate of prior distribution per hour /h |
| | T | Gasifier lock bucket valve | | | M1 | Sealing surface wear | | | M2 | Switch not in place | | | X1 | High-pressure pulverized coal scour | | | X2 | Valve ball and ball seat wear | | | X3 | Ball seat stick together | | | X4 | Deformation and wear of interior parts | | | X5 | Pulverized coal accumulation | | | X6 | The actuator output torque is insufficient | | | X7 | Bearing internal adhesion under high pressure | | | X8 | The pulverized coal enters during the switching process | | | X9 | Water quality is poor | | | X10 | Valve frequent switch | | | X11 | Short time to collect slag | | | X12 | Pressure reducing too fast results in three-phase current scour | |
|
|