Research Article

Reliability Analysis of Gasifier Lock Bucket Valve System Based on DBN Method

Table 2

Failure rates of prior distribution of each node of the gasifier lock bucket valve system.

NodeName of the nodeFailure rate of prior distribution per hour /h

TGasifier lock bucket valve
M1Sealing surface wear
M2Switch not in place
X1High-pressure pulverized coal scour
X2Valve ball and ball seat wear
X3Ball seat stick together
X4Deformation and wear of interior parts
X5Pulverized coal accumulation
X6The actuator output torque is insufficient
X7Bearing internal adhesion under high pressure
X8The pulverized coal enters during the switching process
X9Water quality is poor
X10Valve frequent switch
X11Short time to collect slag
X12Pressure reducing too fast results in three-phase current scour