Review Article

Design Multistage External Gear Pumps for Dry Sump Systems: Methodology and Application

Table 3

Control parameters.

DescriptionValueUnit

Error on target displacement+/-2%
Tip thickness limit0.10mm
Gearing total width limit90.0mm
Backlash minimum limit1.00mm
Contact ratio lower limit1.20—