Review Article
Design Multistage External Gear Pumps for Dry Sump Systems: Methodology and Application
| Description | Value | Unit |
| Error on target displacement | +/-2 | % | Tip thickness limit | 0.10 | mm | Gearing total width limit | 90.0 | mm | Backlash minimum limit | 1.00 | mm | Contact ratio lower limit | 1.20 | ā |
|
|