Review Article
Design Multistage External Gear Pumps for Dry Sump Systems: Methodology and Application
Table 4
Output parameters of gear design.
| Description | Value | Unit |
| Tooth thickness | 5.24 | mm | Stock allowance | 0.30 | mm | Pregrinding rack cutter ad. | 4.42 | mm | Pregrinding profile shift | -0.20 | mm | Root diameter | 30.8 | mm | Form diameter | 36.7 | mm | Operative pressure angle | 26.3 | | Relief groove height ratio | 0.80 | ā | Relief groove height | 7.50 | mm | Pump displacement | 85.9 | | Gearing total width | 89.3 | mm | Backlash | 1.52 | mm | Root clearance | 1.07 | mm | Tip circle tooth thickness | 0.15 | mm | Contact ratio | 1.32 | mm |
|
|