Review Article
Design Multistage External Gear Pumps for Dry Sump Systems: Methodology and Application
Table 8
Comparison between calculated and target flow rates.
| | Pressure drop | Target flow rate | Calculated flow rate | Deviation |
| | 1.0 | 252.0 | 259.4 | +2.9 | 4.0 | 252.0 | 256.0 | +1.6 | 7.0 | 252.0 | 252.0 | +0.0 | 10.0 | 252.0 | 249.1 | −1.2 | | 1.0 | 302.4 | 313.4 | +3.6 | 4.0 | 302.4 | 310.0 | +2.5 | 7.0 | 302.4 | 308.0 | +1.9 | 10.0 | 302.4 | 305.1 | +0.9 | | 1.0 | 384.8 | 356.8 | +1.1 | 4.0 | 384.8 | 354.0 | +0.3 | 7.0 | 384.8 | 351.0 | −0.5 | 10.0 | 384.8 | 347.8 | v1.4 |
|
|