Research Article
A Simulation Method Based on the Candidate Operation Strategies for the Combined Cooling, Heat, and Power (CCHP) System
Table 7
Results of the solution of the optimal model.
| Item | The presented method | The primal dual optimization algorithm |
| Cold load | 392.2 | 392.28 | Heat load | 1104.5 | 1104.5 | Electricity load | 867.1 | 867.12 | Power generation (kWh) | 868.1 | 868.48 | Purchasing electricity from grid (kWh) | 0 | 0 | Selling electricity to grid (kWh) | 0 | 0 | Producing heat energy by boiler (kWh) | 0 | 0 | Cooling by electric chiller (kWh) | 3.96 | 4.15 | Cooling by absorption chiller (kWh) | 388.3 | 388.63 | Operation cost | 1172.00 | 1172.54 |
|
|