Cable maximum temperature and electromagnetic loss with different computational grids (Tsur = 293.15 K, I = 800 A, and f = 50 Hz).
| Cable model | Grid | Region | Maximum grid size (m) | Minimum grid size (m) | Total element number | Tmax (K) | Φloss (W) |
| Flat-type trench laying cable | Grid 1 | Zone 1 | 0.0097 | 0.0024 | 10,881 | 336.520 | 190.65 | Zone 2 | 0.2971 | 0.0049 | Zone 3 | 0.3192 | 0.0199 | Zone 4 | 3.1044 | 0.2489 | Grid 2 | Zone 1 | 0.0057 | 0.0017 | 18,070 | 333.742 | 183.38 | Zone 2 | 0.1137 | 0.0049 | Zone 3 | 0.1815 | 0.0181 | Zone 4 | 2.1844 | 0.1411 | Grid 3 | Zone 1 | 0.0043 | 0.0015 | 27,610 | 333.708 | 182.55 | Zone 2 | 0.0938 | 0.0042 | Zone 3 | 0.1515 | 0.0117 | Zone 4 | 1.8306 | 0.1117 | Grid 4 | Zone 1 | 0.0024 | 0.0013 | 50,188 | 333.541 | 182.25 | Zone 2 | 0.0682 | 0.0020 | Zone 3 | 0.1256 | 0.0117 | Zone 4 | 0.9978 | 0.0951 |
| Trefoil-type trench laying cable | Grid 1 | Zone 1 | 0.0060 | 0.0015 | 14,408 | 342.287 | 190.67 | Zone 2 | 0.1140 | 0.0013 | Zone 3 | 0.1815 | 0.0260 | Zone 4 | 2.5112 | 0.1411 | Grid 2 | Zone 1 | 0.0059 | 0.0015 | 22,618 | 343.014 | 189.69 | Zone 2 | 0.0911 | 0.0012 | Zone 3 | 0.1457 | 0.0227 | Zone 4 | 1.7810 | 0.1088 | Grid 3 | Zone 1 | 0.0047 | 0.0011 | 27,798 | 341.779 | 188.69 | Zone 2 | 0.0885 | 0.0012 | Zone 3 | 0.1173 | 0.0127 | Zone 4 | 0.9868 | 0.1031 | Grid 4 | Zone 1 | 0.0033 | 0.0011 | 53,290 | 341.411 | 188.71 | Zone 2 | 0.0877 | 0.0011 | Zone 3 | 0.1093 | 0.0103 | Zone 4 | 0.4872 | 0.0748 |
|
|