Research Article
A Method for Reconstruction of Boiler Combustion Temperature Field Based on Acoustic Tomography
Table 3
High-low peak temperature field reconstruction error.
| | Reconstruction method | Error in the central area | Error in the edge area | Global error | | (%) | | (%) | | (%) |
| | LSM-BI | 49.32 | 4.34 | \ | \ | 49.32 | 4.34 | | LSM-SP | 50.21 | 4.40 | 129.14 | 13.46 | 88.08 | 9.56 | | ART-SP | 53.19 | 4.71 | 136.31 | 14.17 | 93.07 | 10.09 | | LSM-KR | 50.14 | 4.51 | 102.81 | 11.11 | 75.41 | 8.14 | | EF-RBFI | 42.23 | 3.76 | 103.01 | 9.92 | 71.39 | 7.19 |
|
|