Research Article
A Method for Reconstruction of Boiler Combustion Temperature Field Based on Acoustic Tomography
Table 4
Reconstruction error of the EF-RBFI algorithm with noise.
| | (%) | Type of temperature field | Error in the central area | Error in the edge area | Global error | | (%) | | (%) | | (%) |
| | 1 | Single-peak | 24.59 | 2.05 | 69.17 | 5.67 | 45.98 | 4.08 | | Double-peak | 51.66 | 4.22 | 82.91 | 7.47 | 66.65 | 5.86 | | High-low peak | 47.03 | 4.08 | 108.94 | 10.27 | 76.74 | 7.50 |
| | 3 | Single-peak | 49.25 | 3.67 | 86.34 | 6.89 | 67.05 | 5.35 | | Double-peak | 64.88 | 5.38 | 94.98 | 8.43 | 79.32 | 6.88 | | High-low peak | 62.64 | 5.28 | 122.47 | 11.13 | 91.35 | 8.41 |
| | 5 | Single-peak | 79.49 | 5.57 | 104.23 | 8.35 | 91.36 | 6.94 | | Double-peak | 85.60 | 6.92 | 109.07 | 9.65 | 96.86 | 8.22 | | High-low peak | 83.76 | 6.85 | 137.14 | 12.15 | 109.37 | 9.58 |
|
|