Mathematical Problems in Engineering / 2021 / Article / Tab 2 / Research Article
Lightning Protection Improvement and Economic Evaluation of Thailand’s 24 kV Distribution Line Based on Difference in Grounding Distance of Overhead Ground Wire Table 2 Parameters in ATP-EMTP modeling.
Description Data Lightning current Peak value 40 kA Time to half value 77.5 μ s Time to crest value 0.936/0.411 = 4.12 μ s Conductor (single) Outside diameter 16 mm Direct current resistance 0.2 Ω/km OHGW Outside diameter 7.93 mm Direct current resistance 4.7 Ω/km External ground wire Outside diameter 7.93 mm Impedance (Zt) 408 Ω Speed of lightning wave 300 m/μ s Concrete pole Span of the pole 40 m Height 12 m Single ground rod Diameter of ground rod 16 mm Length of ground rod 2.4 m Ground resistance® 1–30 Ω Earth resistivity 40 Ω·m