Research Article

LQR Active Control of Fractional-Order Pantograph-Catenary System Based on Feedback Linearization

Table 2

Performance index of type I pantograph.

(a) Statistical comparison of pantograph-catenary contact force
Control modesMax/NMin/NMean/NSTD

Passive control167.1446.2098.4620.73
Feedback linearized LQR active control131.6042.2985.1115.97

(b) Statistical comparison of pantograph head displacement
Passive control0.0640.0130.0360.013
Feedback linearized LQR active control0.0510.0110.0300.009