LQR Active Control of Fractional-Order Pantograph-Catenary System Based on Feedback Linearization
Table 4
Statistical comparison between the two control methods (v = 250 km/h).
| (a) Statistical comparison of pantograph-catenary contact force. | Control modes | Max/N | Min/N | Mean/N | STD |
| Passive control | 167.14 | 46.21 | 98.46 | 20.74 | Feedback linearized LQR active control | 131.59 | 42.29 | 85.10 | 15.97 | PID control | 137.24 | 63.69 | 92.40 | 14.25 |
| (b) Statistical comparison of pantograph head displacement. | Passive control | 0.064 | 0.013 | 0.035 | 0.013 | Feedback linearized LQR active control | 0.051 | 0.012 | 0.030 | 0.009 | PID control | 0.051 | 0.016 | 0.033 | 0.010 |
| (c) Statistical comparison of active control force. | Feedback linearized LQR active control | 99.02 | 66.48 | 86.49 | 6.47 | PID active control | 202.98 | -92.92 | 93.07 | 64.27 |
|
|