Research Article
Speed Sensorless Control Based on Initial Rotor Position Detection for EESM
| Specification | Value | Specification | Value |
| Power (kW) | 8 | q-axis armature reaction inductance (mH) | 51.8 | DC link voltage (V) | 380 | Stator winding leakage inductance (mH) | 4.5 | Rated speed (r/min) | 1500 | Rotor winding leakage inductance (mH) | 11.3 | Number of pole pairs | 2 | d-axis damping winding resistance (Ω) | 3.14 | Stator resistance (Ω) | 1.62 | q-axis damping winding resistance (Ω) | 4.77 | Rotor resistance (Ω) | 1.2 | d-axis damping winding leakage inductance (mH) | 7.33 | d-axis armature reaction inductance (mH) | 108.6 | q-axis damping winding leakage inductance (mH) | 10.15 |
|
|