Research Article

Thermal Analysis of Roller Compacted Concrete Dam Utilizing a Probabilistic Model

Table 2

Monte Carlo probabilistic analysis settings in ANSYS software and specifications of the parameters.

ParameterThe standard deviationLower boundMain valueUpper boundNumber of simulation loopsNumber of iteration

Young's modulus73.362546.6162
Thermal conductivity0.51.412.964.5102
Specific heat807239701218102