Research Article

An Embedded Linear Model Three-Dimensional Fuzzy PID Control System for a Bionic AUV under Wave Disturbance

Table 8

Comparison of the control results of classical PID, normal fuzzy PID, and ELM PID controller under the disturbance of three waves in test III.

Simulation resultsClassical PIDNormal fuzzy PIDELM fuzzy PID

Response time of CTD in test III (calm-rippled)6.95 s5.12 s5.56 s
Overshoot of CTD in test III (calm-rippled)0.20 m0.46 m0.13 m
Response time of CTD in test III (smooth-wavelet)7.23 s4.87 s5.26 s
Overshoot of CTD in test III (smooth-wavelet)0.58 m0.65 m0.12 m
Response time of CTD in test III (slight)11.82 s4.91 s4.92 s
Overshoot of CTD in test III (slight)1.12 m0.67 m0.31 m