Research Article

Method of Series Arc Fault Detection Based on Phase Space Reconstruction and Convolutional Neural Network

Table 4

Accuracy of arc fault identification in series with different loads.

Load typeAir conditionerComputerDimming lightsFluorescent lamp 10 WFluorescent lamp 20 WFluorescent lamp 45 WFluorescent lamp 55 WFluorescent lamp 65 WFluorescent lamp 75 WHair dryer hot airHair dryer cold airInduction cooker 2000 WKettleRefrigeratorVacuum cleaner

Accuracy rate (%)939798.297.899.899.699.899.899.694.299.899.810097.698