Research Article
Seismic Vulnerability Assessment of Thermal Power Plants Based on Beta Function
Table 10
Correspondence between seismic intensity and PGA.
| Seismic intensity | 6 (g) | 7 (g) | 8 (g) | 9 (g) | 10 (g) | 11 (g) |
| China’s Code for Seismic Design of Buildings | 0.05 | 0.1 | 0.2 | 0.4 | 0.8 | 1.6 | Trifunac–Brady | 0.07 | 0.13 | 0.26 | 0.53 | 1.05 | 2.10 | MSK | 0.05 | 0.10 | 0.21 | 0.42 | 0.84 | 1.67 | Gutenberg–Richter | 0.03 | 0.07 | 0.15 | 0.32 | 0.70 | 1.50 | Neumann | 0.06 | 0.13 | 0.26 | 0.51 | 1.02 | 2.04 |
|
|