Research Article

Seismic Vulnerability Assessment of Thermal Power Plants Based on Beta Function

Table 10

Correspondence between seismic intensity and PGA.

Seismic intensity6 (g)7 (g)8 (g)9 (g)10 (g)11 (g)

China’s Code for Seismic Design of Buildings0.050.10.20.40.81.6
Trifunac–Brady0.070.130.260.531.052.10
MSK0.050.100.210.420.841.67
Gutenberg–Richter0.030.070.150.320.701.50
Neumann0.060.130.260.511.022.04