Research Article
Application of Grey Deformation Prediction Model Optimized by Double Coefficient for Tailings Dam
Table 10
Predicted deformation of monitoring point 01 by the GDPM-DC.
| Monitoring content | GDPM-DC | Stage | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
| Vertical deformation/mm | Measured value/mm | 7.4 | 11.2 | 11.9 | 13.2 | 14 | 14.6 | 15 | 15.6 | 16.5 | Predicted value/mm | 7.400 | 11.344 | 12.118 | 13.063 | 13.745 | 14.366 | 15.016 | 15.696 | 16.603 | Relative error/% | 0.00 | −1.28 | −1.83 | 1.04 | 1.82 | 1.60 | −0.11 | −0.62 | −0.63 |
| Transverse deformation/mm | Measured value/mm | 4.3 | 9.9 | 11.8 | 13.3 | 15.5 | 16.8 | 17.9 | 19.8 | 21.6 | Predicted value/mm | 4.300 | 10.255 | 11.912 | 13.381 | 14.970 | 16.442 | 18.060 | 19.839 | 21.699 | Relative error/% | 0.00 | −3.58 | −0.95 | −0.61 | 3.42 | 2.13 | −0.89 | −0.20 | −0.46 |
| Seepage pressure/kPa | Measured value/mm | 53.5 | 78.99 | 94.8 | 89.7 | 82.05 | 77.97 | 75.42 | 70.33 | 64.17 | Predicted value/mm | 53.500 | 84.206 | 92.068 | 87.874 | 82.745 | 78.716 | 74.892 | 71.263 | 66.382 | Relative error/% | 0.00 | −6.60 | 2.88 | 2.04 | −0.85 | −0.96 | 0.70 | −1.33 | −3.45 |
|
|