Shear strength under different structural plane sizes.
| Simulation program | Number of joints (bar) | Shear strength under different structural plane sizes (MPa) | Program 1 | Program 2 | Program 3 | Program 4 | Program 5 | Program 6 | 200 mm | 400 mm | 600 mm | 800 mm | 1000 mm | 1200 mm |
| Program 7 | 1 | 224.13 | 111.34 | 71.71 | 56.23 | 44.28 | 35.37 | Program 8 | 3 | 206.15 | 109.28 | 71.29 | 52.32 | 42.87 | 34.43 | Program 9 | 5 | 203.33 | 105.14 | 66.24 | 51.32 | 42.17 | 33.94 | Program 10 | 7 | 199.84 | 97.73 | 65.05 | 50.28 | 40.64 | 32.86 | Program 11 | 9 | 197.65 | 95.64 | 65.23 | 48.92 | 40.11 | 32.45 |
|
|