Research Article

Study on the Interpretation Method of Layered Flow Imaging Logging for Oil–water, Two-Phase Flow in Horizontal Wells

Table 5

The starting flow of pure oil and pure water at 90 degrees.

Fluid compositionMeasurement point height (mm)Start flow (m3/d)Start velocity (m/min)

Pure oil ( = 0%)100582.876699416
88572.301359533
76552.301359533
64704.315049124
481358.054758365
Pure water ( = 100%)100532.876699416
88462.301359533
76372.301359533
64414.315049124
48728.054758365