Research Article
Study on the Interpretation Method of Layered Flow Imaging Logging for Oil–water, Two-Phase Flow in Horizontal Wells
Table 5
The starting flow of pure oil and pure water at 90 degrees.
| Fluid composition | Measurement point height (mm) | Start flow (m3/d) | Start velocity (m/min) |
| Pure oil ( = 0%) | 100 | 58 | 2.876699416 | 88 | 57 | 2.301359533 | 76 | 55 | 2.301359533 | 64 | 70 | 4.315049124 | 48 | 135 | 8.054758365 | Pure water ( = 100%) | 100 | 53 | 2.876699416 | 88 | 46 | 2.301359533 | 76 | 37 | 2.301359533 | 64 | 41 | 4.315049124 | 48 | 72 | 8.054758365 |
|
|