Research Article
Study on the Interpretation Method of Layered Flow Imaging Logging for Oil–water, Two-Phase Flow in Horizontal Wells
Table 6
Turbine speed under pure water condition at 90 degrees (RPS: r/s).
| Flow (m3/d) |
| Measuring point height | 50 | 70 | 100 | 120 | 160 | 200 | 250 | 300 | Measuring point 1 (100 mm) | 0 | 0.36 | 1.64 | 2.04 | 2.79 | 3.51 | 4.5 | 5.38 | Measuring point 2 (88 mm) | 0.56 | 1.16 | 1.7 | 2.14 | 2.96 | 3.68 | 4.61 | 5.58 | Measuring point 3 (76 mm) | 0.67 | 1.09 | 1.69 | 2.11 | 2.93 | 3.65 | 4.64 | 5.6 | Measuring point 4 (64 mm) | 0.51 | 0.87 | 1.49 | 1.99 | 2.76 | 3.47 | 4.42 | 5.34 | Measuring point 5 (48 mm) | 0 | 0 | 0 | 1.48 | 2.31 | 2.7 | 3.72 | 4.35 |
|
|